{"product_id":"100vbfd-b-83-gallon-boiler-feed","title":"100VBFD-B 83 Gallon Boiler Feed","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eSystem downtime during peak heating season is not just an inconvenience; it is a liability that leads to compromised indoor environments, potential pipe damage, and frustrated facility managers. When a boiler feed unit fails, the entire hydronic loop is at risk of cavitation or dry firing. With current supply chain instability and extended lead times for heavy mechanical equipment, waiting for a failure to occur is a high stakes gamble. Securing the Hoffman 100VBFD-B now ensures your projects stay on schedule and your clients remain protected against the inevitable rush of emergency repairs during the first freeze. Planning your equipment procurement ahead of time provides the necessary buffer to avoid back orders and high freight costs while maintaining your reputation for reliability.\u003c\/p\u003e\u003cp\u003eThe Hoffman 100VBFD-B represents a significant technical upgrade over standard light duty condensate units. Its heavy gauge steel receiver and high performance pumping assembly are engineered to handle the thermal stresses of continuous boiler feed service without the premature seal failure common in inferior models. By maintaining a consistent water level and stabilizing return temperatures, this unit reduces the operational strain on the boiler itself. This translates to lower maintenance costs and fewer call backs for your crews. Investing in professional grade equipment like the 100VBFD-B provides a clear competitive edge by delivering a more stable and efficient steam system to the end user.\u003c\/p\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHeavy Gauge Steel Receiver \/ Cast Iron Pump Housing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Capacity\u003c\/td\u003e\n\u003ctd\u003e83 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Configuration\u003c\/td\u003e\n\u003ctd\u003eDuplex (VBFD Series)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rating\u003c\/td\u003e\n\u003ctd\u003eSized for Steam System Returns\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eTypical 115\/230V or 208-230\/460V Configurations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Size\u003c\/td\u003e\n\u003ctd\u003eInferred 2 Inch NPT Inlet \/ 1.25 Inch Discharge\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eEnamel Coated Industrial Blue or Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed Componentry\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eAvailable Models \u0026amp; Sizes\u003c\/h3\u003e\u003cp\u003eThe VBF series is available in several configurations ranging from 30 gallon simplex units to high capacity 250 gallon duplex systems. Contact our technical sales team for precise motor horsepower ratings, phase requirements, and custom control panel options to meet your specific project specifications.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty steel receiver tank designed for long term resistance to corrosion and thermal cycling.\u003c\/li\u003e\n\u003cli\u003eDuplex pump configuration provides built in redundancy to ensure continuous operation if one motor requires service.\u003c\/li\u003e\n\u003cli\u003eHigh temperature mechanical seals specifically rated for boiler feed applications to prevent leaks.\u003c\/li\u003e\n\u003cli\u003eIntegrated float switch assembly for precise water level management and automated make up.\u003c\/li\u003e\n\u003cli\u003eEasy access suction strainers allow for quick cleaning and maintenance without breaking major pipe connections.\u003c\/li\u003e\n\u003cli\u003eLow profile tank design simplifies retrofitting into existing mechanical rooms with limited overhead clearance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCommon Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCommercial landscape irrigation\u003c\/li\u003e\n\u003cli\u003eMunicipal parks and public spaces\u003c\/li\u003e\n\u003cli\u003eGreenhouse and nursery operations\u003c\/li\u003e\n\u003cli\u003eAgricultural and crop irrigation\u003c\/li\u003e\n\u003cli\u003eSports turf and golf course maintenance\u003c\/li\u003e\n\u003cli\u003ePotable water supply systems\u003c\/li\u003e\n\u003cli\u003eChemical\/fertigation delivery\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cp\u003eInstallation should be performed on a level concrete pad with sufficient clearance for motor removal and strainer maintenance. Ensure all piping is properly supported to prevent stress on the pump casings and use isolation valves on the inlet and outlet lines. Always verify that the electrical supply matches the motor nameplate and consult local mechanical codes regarding vent sizing and overflow drainage. A startup bypass should be utilized to flush the system of construction debris before final commissioning.\u003c\/p\u003e","brand":"Hoffman","offers":[{"title":"Default Title","offer_id":52154860241185,"sku":"161004","price":9990.29,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/8458\/3969\/files\/161025_PR.png?v=1766116423","url":"https:\/\/asiwsupply.com\/products\/100vbfd-b-83-gallon-boiler-feed","provider":"ASIW","version":"1.0","type":"link"}