30VBFD-B 18 Gallon Boiler Feed
30VBFD-B 18 Gallon Boiler Feed

30VBFD-B 18 Gallon Boiler Feed

Request to Quote
1k+ bought in past month

Product Overview

System shutdowns during the peak of winter or mid season demand can result in catastrophic pipe damage, expensive emergency service calls, and prolonged facility downtime. When a boiler feed unit fails, the entire hydronic system is compromised, often leading to code violations and angry clients who cannot afford to lose heat or process steam. With global supply chains remains unpredictable, waiting for a failure to occur before ordering a replacement is a high risk strategy that leads to long lead times and lost revenue. Securing your Hoffman 30VBFD-B unit now ensures your projects stay on schedule and your client systems remain operational when failure is not an option.

The Hoffman 30VBFD-B 18 Gallon Boiler Feed unit provides a significant technical advantage over lower grade alternatives by utilizing a heavy gauge steel receiver and a high performance centrifugal pump designed for elevated water temperatures. This unit is engineered to handle the rigorous demands of condensate return and boiler feed service, reducing the frequency of maintenance cycles and lowering long term labor costs for your crews. By installing a professional grade Hoffman system, you provide a reliable solution that prevents pump cavitation and ensures consistent water levels. Maintaining a stock of these critical components gives your business a competitive edge when responding to high stakes municipal or commercial RFPs.

Product Specifications

Specification Detail
Receiver Capacity 18 Gallons
Material Heavy Gauge Steel Receiver
Voltage 115/230V Single Phase
Pump Type Centrifugal Vertical Design
Maximum Temperature 210 Degrees Fahrenheit
Inlet Size 2 Inch NPT
Finish Enamel Coated Gray
Certifications UL Listed and CSA Certified

Available Models & Sizes

The Hoffman VBFD series is available in several configurations ranging from 15 to 100 gallon receiver capacities with various pump horsepower ratings to match specific boiler requirements. Please contact our technical sales team for full configurations, custom pump curves, or bulk pricing for large scale mechanical projects.

Key Features

  • Heavy duty steel receiver tank provides long term resistance to thermal stress and corrosion.
  • Vertical pump design saves valuable floor space in cramped mechanical rooms and simplifies motor access.
  • High temperature seals are specifically rated for boiler feed applications to prevent premature leaking.
  • Self venting casing design prevents air binding to ensure consistent water delivery to the boiler.
  • Pre assembled components reduce field labor time and minimize installation errors for your crews.
  • Precision balanced impellers reduce vibration and noise during operation for quieter facility environments.

Common Applications

  • Commercial landscape irrigation for large scale greenhouse boiler systems.
  • Municipal parks and public spaces utilizing hydronic heating for maintenance facilities.
  • Greenhouse and nursery operations requiring precise humidity and temperature control.
  • Agricultural and crop irrigation systems where steam sterilization is required.
  • Sports turf and golf course maintenance building heat and wash systems.
  • Potable water supply systems requiring high temperature condensate management.

Installation Notes

Installation should be performed by a licensed mechanical contractor in accordance with local plumbing and electrical codes. Ensure the receiver is mounted on a level concrete pad and all suction piping is properly supported to prevent stress on the pump casing. It is recommended to install a bypass line and isolation valves to allow for future maintenance without draining the entire system. Verify that the electrical supply matches the motor nameplate before startup and check for proper rotation on all centrifugal pumps.

Out of Stock
FREE delivery today. Order within
Order soon.
Ships fromVero Beach, Florida
BrandBerkeley
Product Overview

System shutdowns during the peak of winter or mid season demand can result in catastrophic pipe damage, expensive emergency service calls, and prolonged facility downtime. When a boiler feed unit fails, the entire hydronic system is compromised, often leading to code violations and angry clients who cannot afford to lose heat or process steam. With global supply chains remains unpredictable, waiting for a failure to occur before ordering a replacement is a high risk strategy that leads to long lead times and lost revenue. Securing your Hoffman 30VBFD-B unit now ensures your projects stay on schedule and your client systems remain operational when failure is not an option.

The Hoffman 30VBFD-B 18 Gallon Boiler Feed unit provides a significant technical advantage over lower grade alternatives by utilizing a heavy gauge steel receiver and a high performance centrifugal pump designed for elevated water temperatures. This unit is engineered to handle the rigorous demands of condensate return and boiler feed service, reducing the frequency of maintenance cycles and lowering long term labor costs for your crews. By installing a professional grade Hoffman system, you provide a reliable solution that prevents pump cavitation and ensures consistent water levels. Maintaining a stock of these critical components gives your business a competitive edge when responding to high stakes municipal or commercial RFPs.

Product Specifications
Specification Detail
Receiver Capacity 18 Gallons
Material Heavy Gauge Steel Receiver
Voltage 115/230V Single Phase
Pump Type Centrifugal Vertical Design
Maximum Temperature 210 Degrees Fahrenheit
Inlet Size 2 Inch NPT
Finish Enamel Coated Gray
Certifications UL Listed and CSA Certified
Available Models & Sizes

The Hoffman VBFD series is available in several configurations ranging from 15 to 100 gallon receiver capacities with various pump horsepower ratings to match specific boiler requirements. Please contact our technical sales team for full configurations, custom pump curves, or bulk pricing for large scale mechanical projects.

Key Features
  • Heavy duty steel receiver tank provides long term resistance to thermal stress and corrosion.
  • Vertical pump design saves valuable floor space in cramped mechanical rooms and simplifies motor access.
  • High temperature seals are specifically rated for boiler feed applications to prevent premature leaking.
  • Self venting casing design prevents air binding to ensure consistent water delivery to the boiler.
  • Pre assembled components reduce field labor time and minimize installation errors for your crews.
  • Precision balanced impellers reduce vibration and noise during operation for quieter facility environments.
Common Applications
  • Commercial landscape irrigation for large scale greenhouse boiler systems.
  • Municipal parks and public spaces utilizing hydronic heating for maintenance facilities.
  • Greenhouse and nursery operations requiring precise humidity and temperature control.
  • Agricultural and crop irrigation systems where steam sterilization is required.
  • Sports turf and golf course maintenance building heat and wash systems.
  • Potable water supply systems requiring high temperature condensate management.
Installation Notes

Installation should be performed by a licensed mechanical contractor in accordance with local plumbing and electrical codes. Ensure the receiver is mounted on a level concrete pad and all suction piping is properly supported to prevent stress on the pump casing. It is recommended to install a bypass line and isolation valves to allow for future maintenance without draining the entire system. Verify that the electrical supply matches the motor nameplate before startup and check for proper rotation on all centrifugal pumps.

Top Reviews