{"product_id":"30vbfd-b-18-gallon-boiler-feed","title":"30VBFD-B 18 Gallon Boiler Feed","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\u003cp\u003eSystem shutdowns during the peak of winter or mid season demand can result in catastrophic pipe damage, expensive emergency service calls, and prolonged facility downtime. When a boiler feed unit fails, the entire hydronic system is compromised, often leading to code violations and angry clients who cannot afford to lose heat or process steam. With global supply chains remains unpredictable, waiting for a failure to occur before ordering a replacement is a high risk strategy that leads to long lead times and lost revenue. Securing your Hoffman 30VBFD-B unit now ensures your projects stay on schedule and your client systems remain operational when failure is not an option.\u003c\/p\u003e\u003cp\u003eThe Hoffman 30VBFD-B 18 Gallon Boiler Feed unit provides a significant technical advantage over lower grade alternatives by utilizing a heavy gauge steel receiver and a high performance centrifugal pump designed for elevated water temperatures. This unit is engineered to handle the rigorous demands of condensate return and boiler feed service, reducing the frequency of maintenance cycles and lowering long term labor costs for your crews. By installing a professional grade Hoffman system, you provide a reliable solution that prevents pump cavitation and ensures consistent water levels. Maintaining a stock of these critical components gives your business a competitive edge when responding to high stakes municipal or commercial RFPs.\u003c\/p\u003e\u003ch3\u003eProduct Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eReceiver Capacity\u003c\/td\u003e\n\u003ctd\u003e18 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaterial\u003c\/td\u003e\n\u003ctd\u003eHeavy Gauge Steel Receiver\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e115\/230V Single Phase\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eCentrifugal Vertical Design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd\u003e210 Degrees Fahrenheit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInlet Size\u003c\/td\u003e\n\u003ctd\u003e2 Inch NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinish\u003c\/td\u003e\n\u003ctd\u003eEnamel Coated Gray\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eUL Listed and CSA Certified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003ch3\u003eAvailable Models \u0026amp; Sizes\u003c\/h3\u003e\u003cp\u003eThe Hoffman VBFD series is available in several configurations ranging from 15 to 100 gallon receiver capacities with various pump horsepower ratings to match specific boiler requirements. Please contact our technical sales team for full configurations, custom pump curves, or bulk pricing for large scale mechanical projects.\u003c\/p\u003e\u003ch3\u003eKey Features\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHeavy duty steel receiver tank provides long term resistance to thermal stress and corrosion.\u003c\/li\u003e\n\u003cli\u003eVertical pump design saves valuable floor space in cramped mechanical rooms and simplifies motor access.\u003c\/li\u003e\n\u003cli\u003eHigh temperature seals are specifically rated for boiler feed applications to prevent premature leaking.\u003c\/li\u003e\n\u003cli\u003eSelf venting casing design prevents air binding to ensure consistent water delivery to the boiler.\u003c\/li\u003e\n\u003cli\u003ePre assembled components reduce field labor time and minimize installation errors for your crews.\u003c\/li\u003e\n\u003cli\u003ePrecision balanced impellers reduce vibration and noise during operation for quieter facility environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCommon Applications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eCommercial landscape irrigation for large scale greenhouse boiler systems.\u003c\/li\u003e\n\u003cli\u003eMunicipal parks and public spaces utilizing hydronic heating for maintenance facilities.\u003c\/li\u003e\n\u003cli\u003eGreenhouse and nursery operations requiring precise humidity and temperature control.\u003c\/li\u003e\n\u003cli\u003eAgricultural and crop irrigation systems where steam sterilization is required.\u003c\/li\u003e\n\u003cli\u003eSports turf and golf course maintenance building heat and wash systems.\u003c\/li\u003e\n\u003cli\u003ePotable water supply systems requiring high temperature condensate management.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eInstallation Notes\u003c\/h3\u003e\u003cp\u003eInstallation should be performed by a licensed mechanical contractor in accordance with local plumbing and electrical codes. Ensure the receiver is mounted on a level concrete pad and all suction piping is properly supported to prevent stress on the pump casing. It is recommended to install a bypass line and isolation valves to allow for future maintenance without draining the entire system. Verify that the electrical supply matches the motor nameplate before startup and check for proper rotation on all centrifugal pumps.\u003c\/p\u003e","brand":"Hoffman","offers":[{"title":"Default Title","offer_id":52154860175649,"sku":"161025","price":7147.47,"currency_code":"USD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/8458\/3969\/files\/161025_PR_54feb523-d898-4c9b-b127-7ef2bb6b088c.png?v=1766116506","url":"https:\/\/asiwsupply.com\/products\/30vbfd-b-18-gallon-boiler-feed","provider":"ASIW","version":"1.0","type":"link"}