50VBFS-B 39 Gallon Boiler Feed
50VBFS-B 39 Gallon Boiler Feed

50VBFS-B 39 Gallon Boiler Feed

Request to Quote
1k+ bought in past month

Product Overview

System shutdowns during the peak of heating season are more than just an inconvenience; they are a threat to your reputation and your client's operations. When a boiler feed unit fails, the entire hydronic system grinds to a halt, risking catastrophic equipment damage, frozen pipes, and costly code violations. With late season demand spiking and industrial supply chains still facing erratic lead times, waiting for a failure to occur is a high stakes gamble. Securing your Hoffman 50VBFS-B unit now ensures your projects stay on schedule and your service contracts remain unbroken, providing the relief of a fully operational system before the first frost hits.

The Hoffman 50VBFS-B offers a significant technical advantage over lower grade alternatives through its heavy duty cast iron receiver and precision engineered centrifugal pumps. While lighter steel tanks succumb to corrosion and pitting within a few seasons, this vertical design is built for decades of reliable service in demanding mechanical rooms. By choosing a professional grade 39 gallon unit, your crews spend less time on emergency repairs and more time on new installations. Being properly stocked with high performance Hoffman equipment gives your firm a competitive edge, as you can guarantee long term uptime that hardware store alternatives simply cannot match.

Product Specifications

Specification Detail
Material Cast Iron Receiver with Bronze Fitted Pumps
Tank Capacity 39 Gallons
Pump Configuration Vertical Centrifugal (Simplex or Duplex compatible)
Electrical Requirement Standard Industrial Voltage configurations available
Max Operating Pressure Rated for high pressure steam applications
Finish Corrosion resistant industrial enamel

Available Models & Sizes

The Hoffman 50VBFS series is available in several configurations tailored to specific boiler horsepower requirements, including various pump motor sizes and vertical tank capacities ranging from 30 to over 100 gallons. Please contact our technical sales team for full configurations, custom float switch setups, or bulk project pricing for large scale mechanical retrofits.

Key Features

  • Cast iron receiver body provides superior corrosion resistance compared to thin walled steel tanks.
  • Space saving vertical design reduces the footprint in crowded mechanical rooms and boiler basements.
  • Precision balanced bronze impellers minimize vibration and extend the service life of motor bearings.
  • Heavy duty float switch assembly ensures accurate water level management and prevents pump cavitation.
  • Low inlet height allows for versatile gravity return configurations in existing steam systems.
  • Industrial grade motors are designed for high cycle counts and continuous operation during peak load.

Common Applications

  • Commercial landscape irrigation for large scale greenhouse heating.
  • Greenhouse and nursery operations requiring consistent steam for soil sterilization.
  • Municipal parks and public spaces with centralized district heating systems.
  • Agricultural and crop irrigation support via steam powered pump stations.
  • Sports turf and golf course maintenance facilities with dedicated wash down heaters.
  • Potable water supply systems utilizing steam heat exchangers for temperature control.

Installation Notes

Installation of the 50VBFS-B requires standard mechanical tools and should be performed by a licensed pipefitter or boiler technician. Ensure the unit is mounted on a level concrete pad to prevent stress on the cast iron flanges and piping connections. Always verify that the electrical supply matches the motor nameplate and that all local pressure vessel codes are strictly followed. Hoffman recommends installing a strainer on the return line to prevent pipe scale from entering the receiver and damaging the internal pump components.

Out of Stock
FREE delivery today. Order within
Order soon.
Ships fromVero Beach, Florida
BrandBerkeley
Product Overview

System shutdowns during the peak of heating season are more than just an inconvenience; they are a threat to your reputation and your client's operations. When a boiler feed unit fails, the entire hydronic system grinds to a halt, risking catastrophic equipment damage, frozen pipes, and costly code violations. With late season demand spiking and industrial supply chains still facing erratic lead times, waiting for a failure to occur is a high stakes gamble. Securing your Hoffman 50VBFS-B unit now ensures your projects stay on schedule and your service contracts remain unbroken, providing the relief of a fully operational system before the first frost hits.

The Hoffman 50VBFS-B offers a significant technical advantage over lower grade alternatives through its heavy duty cast iron receiver and precision engineered centrifugal pumps. While lighter steel tanks succumb to corrosion and pitting within a few seasons, this vertical design is built for decades of reliable service in demanding mechanical rooms. By choosing a professional grade 39 gallon unit, your crews spend less time on emergency repairs and more time on new installations. Being properly stocked with high performance Hoffman equipment gives your firm a competitive edge, as you can guarantee long term uptime that hardware store alternatives simply cannot match.

Product Specifications
Specification Detail
Material Cast Iron Receiver with Bronze Fitted Pumps
Tank Capacity 39 Gallons
Pump Configuration Vertical Centrifugal (Simplex or Duplex compatible)
Electrical Requirement Standard Industrial Voltage configurations available
Max Operating Pressure Rated for high pressure steam applications
Finish Corrosion resistant industrial enamel
Available Models & Sizes

The Hoffman 50VBFS series is available in several configurations tailored to specific boiler horsepower requirements, including various pump motor sizes and vertical tank capacities ranging from 30 to over 100 gallons. Please contact our technical sales team for full configurations, custom float switch setups, or bulk project pricing for large scale mechanical retrofits.

Key Features
  • Cast iron receiver body provides superior corrosion resistance compared to thin walled steel tanks.
  • Space saving vertical design reduces the footprint in crowded mechanical rooms and boiler basements.
  • Precision balanced bronze impellers minimize vibration and extend the service life of motor bearings.
  • Heavy duty float switch assembly ensures accurate water level management and prevents pump cavitation.
  • Low inlet height allows for versatile gravity return configurations in existing steam systems.
  • Industrial grade motors are designed for high cycle counts and continuous operation during peak load.
Common Applications
  • Commercial landscape irrigation for large scale greenhouse heating.
  • Greenhouse and nursery operations requiring consistent steam for soil sterilization.
  • Municipal parks and public spaces with centralized district heating systems.
  • Agricultural and crop irrigation support via steam powered pump stations.
  • Sports turf and golf course maintenance facilities with dedicated wash down heaters.
  • Potable water supply systems utilizing steam heat exchangers for temperature control.
Installation Notes

Installation of the 50VBFS-B requires standard mechanical tools and should be performed by a licensed pipefitter or boiler technician. Ensure the unit is mounted on a level concrete pad to prevent stress on the cast iron flanges and piping connections. Always verify that the electrical supply matches the motor nameplate and that all local pressure vessel codes are strictly followed. Hoffman recommends installing a strainer on the return line to prevent pipe scale from entering the receiver and damaging the internal pump components.

Top Reviews