Product Overview

A pump failure in a hazardous location is not just a service call; it is a critical system shutdown that risks code violations, environmental contamination, and severe safety hazards. During peak construction cycles and heavy rainfall seasons, the demand for explosion proof equipment creates significant supply chain bottlenecks. Securing your Goulds 3SDX12H2HC now prevents the project delays that occur when inferior units fail or when standard pumps are flagged during a fire marshal inspection. Planning your inventory ahead of the summer push ensures your clients stay operational while your competitors are stuck waiting on long factory lead times.

The Goulds 3SDX Series distinguishes itself through its Class 1, Division 1, Group C and D rating, offering a level of safety and reliability that standard effluent pumps cannot match. By installing a high head dual seal unit, your crews spend less time on repeated maintenance and more time on new billable projects. The heavy duty cast iron construction and high efficiency impeller design reduce long term energy costs and wear on the motor. Investing in this professional grade equipment provides your firm with a technical advantage, as you can claim higher reliability benchmarks and lower total cost of ownership for your municipal and industrial clients.

Product Specifications

Specification Detail
Material Cast Iron Casing and Impeller
Voltage 230V / 460V Three Phase
Horsepower 1.5 HP to 5 HP Range
Discharge Size 3 Inch ANSI Flange
Hazardous Rating Class 1, Division 1, Group C and D
Maximum Solid Size 2.5 Inch Spherical
Seal Type Dual Mechanical with Seal Sensor
Finish Powder Coated Epoxy

Available Models & Sizes

The 3SDX Series is available in various horsepower configurations starting at 1.5 HP up to 5 HP, with options for different impeller trims to meet specific head and flow requirements. Please contact our technical sales team for full configurations, performance curves, and specific pricing for custom configurations.

Key Features

  • Explosion proof design certified for Class 1, Division 1 hazardous environments.
  • Dual mechanical seals provide an extra layer of protection against motor chamber flooding.
  • Heavy duty cast iron volute and impeller for superior abrasion resistance in sewage applications.
  • Air filled motor design simplifies field maintenance and heat dissipation during long run cycles.
  • Standardized 3 inch ANSI flange connections ensure compatibility with existing rail systems and piping.
  • Internal moisture sensory leads alert operators to seal failure before the motor is compromised.

Common Applications

  • Commercial landscape irrigation with reclaimed water.
  • Municipal parks and public spaces with high traffic restrooms.
  • Agricultural and crop irrigation involving waste processing.
  • Chemical and fertigation delivery in industrial greenhouse settings.
  • Erosion control and stormwater systems in hazardous zones.
  • Potable water supply systems requiring explosion proof failsafes.

Installation Notes

Installers must ensure all wiring follows local electrical codes for hazardous locations, including the use of explosion proof conduit and seal offs. This pump should be used with a compatible Goulds moisture and temperature sensing control panel to maintain the warranty and ensure automatic shutdown in the event of a seal breach. Always verify that the basin depth and rail system alignment allow for proper seating of the ANSI flange before final activation.

Out of Stock
FREE delivery today. Order within
Order soon.
Ships fromVero Beach, Florida
BrandBerkeley
Product Overview

A pump failure in a hazardous location is not just a service call; it is a critical system shutdown that risks code violations, environmental contamination, and severe safety hazards. During peak construction cycles and heavy rainfall seasons, the demand for explosion proof equipment creates significant supply chain bottlenecks. Securing your Goulds 3SDX12H2HC now prevents the project delays that occur when inferior units fail or when standard pumps are flagged during a fire marshal inspection. Planning your inventory ahead of the summer push ensures your clients stay operational while your competitors are stuck waiting on long factory lead times.

The Goulds 3SDX Series distinguishes itself through its Class 1, Division 1, Group C and D rating, offering a level of safety and reliability that standard effluent pumps cannot match. By installing a high head dual seal unit, your crews spend less time on repeated maintenance and more time on new billable projects. The heavy duty cast iron construction and high efficiency impeller design reduce long term energy costs and wear on the motor. Investing in this professional grade equipment provides your firm with a technical advantage, as you can claim higher reliability benchmarks and lower total cost of ownership for your municipal and industrial clients.

Product Specifications
Specification Detail
Material Cast Iron Casing and Impeller
Voltage 230V / 460V Three Phase
Horsepower 1.5 HP to 5 HP Range
Discharge Size 3 Inch ANSI Flange
Hazardous Rating Class 1, Division 1, Group C and D
Maximum Solid Size 2.5 Inch Spherical
Seal Type Dual Mechanical with Seal Sensor
Finish Powder Coated Epoxy
Available Models & Sizes

The 3SDX Series is available in various horsepower configurations starting at 1.5 HP up to 5 HP, with options for different impeller trims to meet specific head and flow requirements. Please contact our technical sales team for full configurations, performance curves, and specific pricing for custom configurations.

Key Features
  • Explosion proof design certified for Class 1, Division 1 hazardous environments.
  • Dual mechanical seals provide an extra layer of protection against motor chamber flooding.
  • Heavy duty cast iron volute and impeller for superior abrasion resistance in sewage applications.
  • Air filled motor design simplifies field maintenance and heat dissipation during long run cycles.
  • Standardized 3 inch ANSI flange connections ensure compatibility with existing rail systems and piping.
  • Internal moisture sensory leads alert operators to seal failure before the motor is compromised.
Common Applications
  • Commercial landscape irrigation with reclaimed water.
  • Municipal parks and public spaces with high traffic restrooms.
  • Agricultural and crop irrigation involving waste processing.
  • Chemical and fertigation delivery in industrial greenhouse settings.
  • Erosion control and stormwater systems in hazardous zones.
  • Potable water supply systems requiring explosion proof failsafes.
Installation Notes

Installers must ensure all wiring follows local electrical codes for hazardous locations, including the use of explosion proof conduit and seal offs. This pump should be used with a compatible Goulds moisture and temperature sensing control panel to maintain the warranty and ensure automatic shutdown in the event of a seal breach. Always verify that the basin depth and rail system alignment allow for proper seating of the ANSI flange before final activation.

Top Reviews